Wednesday, March 10, 2010

Re: [MW:4515] ASTM A216 Vs ASME SA216 Difference

Dear Muthu
 
There are few differences between SA material and ASTM material.  If you require SA216 material, please refer to the Sec. II Part A 2007 Edition and read the fine print under the ASME Monogram which reads (Identical with ASTM A216/A 216M-93 except for the addition of 2.3 and editorial differences in 2.1 and 10.1)
 
For any material please refer to such fine prints.  However, this is mostly applicable when the product has to be code stamped.Test certificate to be reviewed for compliance with SA material including the year and recertification is also to be done.
 
Hope this clarifies your doubts. 
 Regards
 
Gopu Nair

--- On Tue, 9/3/10, vijay frnds <frndstovijay@gmail.com> wrote:

From: vijay frnds <frndstovijay@gmail.com>
Subject: [MW:4502] ASTM A216 Vs ASME SA216 Difference
To: materials-welding@googlegroups.com
Date: Tuesday, 9 March, 2010, 2:42 PM

Dear friends,


I have received the customer order for pipeline valves with ASME SA216 Gr WCB.

My doubt is there any diff. between ASTM A216 Gr WCB Vs ASME SA216 Gr WCB.

Thank you,


--
Urs . . .
Muthu
Smile make(s)miles ! ! !
Please don't print this e-mail unless you really need to! - this will preserve trees on our planet earth.
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.


Your Mail works best with the New Yahoo Optimized IE8. Get it NOW!.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

[MW:35614] Re: SS FILLER

dear , pl check A number and Gas composition use for ss cant be sutibale same % for duplex., u need to qualified with aditional testing of f...