Wednesday, July 1, 2009

[MW:2607] Re: LTCS piping material for MDMT - 60 °C

Dear All
 
I had used SA333 Gr.6 for our sphere piping job having MDMT -60 °C the value we got is much more higher than B31.3 so i think above material is acceptable/sustain for -60 °C. And to prove it, u can go head for Procedure Qualification.
 
Regards
 
Jivan Dhamane

--- On Wed, 1/7/09, BR <raghurambathula@gmail.com> wrote:

From: BR <raghurambathula@gmail.com>
Subject: [MW:2606] LTCS piping material for MDMT - 60 °C
To: "Materials & Welding" <materials-welding@googlegroups.com>
Date: Wednesday, 1 July, 2009, 7:05 PM


Thank you for sharing, but even it is accepted, is it advisable to use
SA 333 Gr6 or better switch to Gr3 what is your opinion?.
What is your experience on energy values when tested at -60 °C. are
they consistent?

I have many failures, in particular sub size specimens when tested for
< - 60 °C.

On Jul 1, 10:39 am, pjo...@technip.com wrote:
> Dear all,
>
> may be useful for the group members.
>
> With best regards,
>
> Prasad Joshi
>
> PIPING
>
> --------------------------------------------------------------------------- --------------------------------------------------------------------------- --------------------------------------------------------------------------- --------------------------------------------------------------------------- -------------------------------------------------------------------
> >
> ----- Forwarded by Prasad Joshi/TPGAUH on 01/07/09 10:39 AM -----
>
>              Prasad                                                        
>              Joshi/TPGAUH                                                  
>                                                                         To
>              01/07/09 10:23 AM         "Ingale, Makarand"                  
>                                        <Makarand.Ing...@petrofac.com>@TECH
>                                        NIP-EXT                            
>                                                                         cc
>
>                                                                    Subject
>                                        Re: Help(Document link: Prasad      
>                                        Joshi)                              
>
> Dear Makarand
>
> Coming to your query, as per ASME B31.3 ASTM A 333/6 can be used below
> -45.5-deg. C (-50-deg. F as allowed by code without any special
> precautions) with following precautions:
>
> 1) Testing of Base metal at minimum design temperature (-60 deg C in your
> case.) as per B-3 of table 323.2.2 of B31.3. This is useful for the
> procurement part.
> 2) For fabrication and welding part, special precaution has to be specified
> for impact testing of Weld metal and HAZ. This is useful for specifying in
> the welding specification or construction specification. You will have to
> specially mention this in the p.class so that it will be highlighted to
> QA/QC or welding engineer.
>
> I hope this clarifies. Let me know if you need any further information.
>
> With best regards,
>
> Prasad Joshi
>
> PIPING

>              "Ingale,                                                      
>              Makarand"                                                    
>              <Makarand.Ingale@                                          To
>              petrofac.com>             <pjo...@technip.com>                
>                                                                         cc
>              01/07/09 09:40 AM                                            
>                                                                    Subject
>                                        Help                                
>
> Dear Prasad,
> I need your help. Can we use Material A333 Gr.6 for temp. Bellow -46 deg.C.
> If yes then what backup document I should refer to prove it. I remember we
> have used this material upto -60 Deg. C, but I don't have any backup
> document to prove it. . if you have anything can you forward me.
> -Makarand.
 

Looking for local information? Find it on Yahoo! Local --~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

[MW:35346] Cast-iron welding

Any advice for cast iron welding Sent from Yahoo Mail for iPhone