Thats the way industry is giving. There is no problem in quality. Quality depends on the co.Thats why mosy clients give list of brands which are acceptable.
Aleternative is to qualify electrode by taking all weld sample which is very expensive and not worth the effort

Rgds
Prakash Gotimukul
AIS, Consultant ASME/ISO/PED/IBR
 Mob:+97152 979 5678

On Fri, Oct 21, 2016 at 2:30 PM, Kumar <sk7920541@gmail.com> wrote:
Dear Experts,

Greetings.

Requesting the views on MTCs (EN 10204 ) for electrode  ( SFA/AWS A
5.1 E 7018-1 H 4 R, 4.00mm). In fact according to project spec. it
should be 3.1. but the contractor could only provide 3.1 for chemical
& mechanical 2.2 in a single MTC.

Since its a deviation from the spec., how far this will affect the
quality of the product when mechanical according to 2.2 & chemical
according to 3.1? how this could be convinced to the end user.

Your valuable feedbacks are appreciated.

thanking in advance,
Kumar.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CALuBtp9j4g08J_sEsjtQ15OF2%2BUyZh8k1v9ky8arTPB53bbVtA%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

--
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAOUP4qKAcVHHN5Bt%3D%2Bux8q0JL_niipD%3Dwc7nj%3Dm_pu%3DgJdp4aQ%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

No comments:

[MW:34916] Applicability of Impact requirement as per ASME B31.3

Dear All, Design code – ASME B31.3, Welding Code- ASME BPVC SEC IX Material  to be used used during Fabrication - SA 333Gr6 (P No.1 G...