Friday, May 2, 2025

[MW:35567] DISTORSION

Dear Experts
Pl share AIR FIN FAN cooler SS316 MOC fabrication sequence to avoid partition plate distortion
Thr partition plate is distorting in its full length after full welding the corner 4nos (32 mm groove )of Square Box Header welds
GTAW + SAW is used

Pl guide

Sent from my iPhone

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/2E591BA9-F1C2-4331-8B27-A395AF0477D8%40gmail.com.

No comments:

Re: [MW:35737] Bend Test and Tensile Test failed for ET45 Micro Welded Coupon

Hi As its %elongation is very low  Better try buttering on jt surrace with ductile consumable like pure Ni i. E Ni1 And later weld jt with c...