Did you perform pwht after the repair 

Στις Κυρ, 23 Ιουν 2019, 17:57 ο χρήστης Roshan Patel <patelroshankk@gmail.com> έγραψε:
Dear Experts,

I have one situation I have a job of material SA 182 F92. Hardness required for this material is 269 HBW Max. We had weld the F92 to F92 material. After PWHT we got Hardness around 250 HBW. But after Radiography it was one defect and we repair it. Now the Hardness of repaired portion is around 340 HBW. Now how we reduce it. And what is the Hardness limit of F92 Weld joints ? 

On Fri 21 Jun, 2019, 10:23 AM , <materials-welding@googlegroups.com> wrote:
Kamal Basha <basha2070@gmail.com>: Jun 20 08:51AM +0300

Api 510 inspection interval
 
If remaining life is 10 years or less
Inspection interval has it is.
 
If remaining life is greater than 10 years
1/2 of the life is inspection interval
...more
Kamal Basha <basha2070@gmail.com>: Jun 20 08:33AM +0300

Both together
 
...more
Chiranjeevi A <chiranjeevipuvvula@gmail.com>: Jun 20 07:24AM +0100

Dear all,
 
We have a situation that we need to weld cap (material P11) to weldolet
with P22 material. Size 2" NPS. Line temp is 560C and pressure 48bar. The
rating of the main header is 1500# P22 ...more
K K <karan.hbl@gmail.com>: Jun 20 05:14AM -0700

Dear Experts,
 
Please clarify me regarding below mentioned doubts.
As per AWS D1.1
 
1) As per PQR thickness qualified with 25mm(Test coupon )
 
 
But In WPS thickness mentioned 28MM ( 3.2mm ...more
You received this digest because you're subscribed to updates for this group. You can change your settings on the group membership page.
To unsubscribe from this group and stop receiving emails from it send an email to materials-welding+unsubscribe@googlegroups.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAHABvdWVHFLn6B63VsKJXjcVpiuWD1j92ZJSGOi3spAmT%3DHMaw%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAPOi40A8kbOUexgrXD8qwUfd23euhXxY2dM7tfYOuKHw%2BD%3D1%3Dg%40mail.gmail.com.
For more options, visit https://groups.google.com/d/optout.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...