Dear experts,
-- we have situation is here one of our welder selected wrong filler material,
To weld 304L to 304L as per wps it was selected ER308L.
One of our welder welded with ER316L we have found this after completion of weld in the PMI results where MO content is showing 2.0%.
Is that acceptable to weld higher grade electrode for 304L piping.
Regards
Reddy.M
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To post to this group, send email to materials-welding@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/3b99f624-8c97-4143-8a84-82ff9352252c%40googlegroups.com.