On Mon, Feb 11, 2013 at 6:45 PM, Dinesh <som.din@gmail.com> wrote:
Dear sir,
please find attached photos for your reference,with raw material defects.This beams are UC 356*368*153 IN Section are flange concavity 4 mm.Please confirm can anybody tell me whats an acceptance criteria for concavity AS per EN10034.We check in standard but it's not clearly mentioned about acceptance limit.
current status : material under hold / clarification
waiting for your reply.
thanks & regards
dinesh
dubai
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
No comments: