Saturday, February 23, 2013

[MW:16850] Welding Repair of 5% Ni steel

Dear Experts,

Query:

1. Can it be possible to use DC power source, using ENiCrMo-6 electrode for base metal containing 5% Ni (5% Ni Steel for LNG tank-cryogenic application) crack welding?
2. Can it be possible to attend repair having following details:
Crack Length=500 mm linear throughout base material
Thickness=13.5 mm
Base Metal=5% Ni Steel
Electrode=ENiCrMo-6, AC power source
Application=LNG carrier (MDMT is around -105°C)

or else have to do patch up (renewal of plate) welding? If yes then suggest to avoid patch up with recommended repair procedure/standard.

Note: As per IACS (Ship Repair Standard) maximum allowable crack length is 500mm & depth=0.5t or else preferred for renewal of plate.

 
Thanks & Regards,
Maulik H. Thakkar
Welding Engieer

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
 
 

No comments:

[MW:34866] Presentation for WPS ,PQR AND WPQ as per ASME Sec IX in power point

Dear Experts.        If anyone having presentation of WPS,PQR and WPQ  as per ASME  SEC.IX  in power point then please share . Regards Sanja...