We are welded DSS A790 UNS S31803 Pipe to pipe PQR welding and we sent it for Mechanical test. But we found PITTING.
The details are below and i attached the test result also.
Material : A 790 UNS S31803 (Pipe to Pipe)
Size : 4" X 8.56mm
Filler Used : ER2209 (Metrode) 2.4mm
Max. Interpass : Below 50ºC
Max. Heat Input : 1.2 KJ/MM
Test Method : ASTM 923 Methode C (22ºC – 24HRS)
Now we are planning to do the PQR again. So please give me you idea to avoid the failure again.
Thanks.
--
Regards,
E.Subramanian
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
No comments: