Saturday, February 2, 2013

[MW:16667] welder performance for overlay qualification.

Respected Experts,
Às per qw-453  for corrosion resistant overlay welder qualification in note 1 there is mention that min. Plate dimen. Is 150 by 150  on which 38 mm min.wide overlay is must.but on other side in note 1 say that for welding processes if width of layer is greater than 13mm then min. Of 3 beads should be deposited in the first layer ,please clarrify this point clearly.

And also reply about weaving in overlay how much it should be?

Thanks & Regards,

Mohit Aggarwal

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
http://www.linkedin.com/groups/MaterialsWelding-122787?home=&gid=122787&trk=anet_ug_hm
 
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
For more options, visit https://groups.google.com/groups/opt_out.
 
 

No comments:

[MW:34920] Tubesheet Hole step

Hello Team, I have one question any tolerance given for tubesheet Hole step. Please do needful. Regards, AP  -- https://materials-...