can some body help me to solve the following problem:
our dished head manufacturer fabricated an stainlees steel
trorespherical head (ID: 5000 mm) by spinning machine we found a
lamination defect in the knuckle area outside of the acceptance
criteria (as per ASME 435 , 75 mm diameter) how can we repair it? is
that allowed as per ASME standard, which article/
many thanks in advance
MA100
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---