[MW:1154] Re: FCAW --- UT / RT ???

groove angle, fcaw gas cup size, gas flow, wind protection etc. to be checked.
 


 
2008/9/19 PREM SHANKARDUTT NAUTIYAL <prem_nautiyal@rediffmail.com>

 
Dear Friends

We are presently using FCAW process(E71T-1) for welding SA516Gr.70 material in 3G and 1G. The joint calls for 100% RT and UT. The thickness is 70mm with double V.
But everytime we get repair in the weld like slag, LOF,porosities..

So my basic question is can FCAW be used to weld RT and UT joints??
If yes what is the correct procedure / precautions to be followed..

Regards

Prem Nautiyal

PREM S NAUTIYAL
CELL : 9820313278

--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...