Friday, February 29, 2008

[MW:635] Re: Etch structure acceptance in IGC test per ASTM A262


The practice E table 5 specifies that for all grades Ditch structure as non acceptable. step, dual, end grain I and II as acceptable structure.

This is as per A262-02a e3 edition.

With regards,
Kannan Sundaram.




"Bathula Raghuram \(Mumbai - PIPING\)" <R.Bathula@ticb.com>
Sent by: materials-welding@googlegroups.com

29/02/2008 12:27

Please respond to
materials-welding@googlegroups.com

To
"Materials & Welding" <materials-welding@googlegroups.com>
cc
Subject
[MW:634] Etch structure acceptance in IGC test per ASTM A262





ASTM A 262 Practice E does not specify anything about the acceptance of Interdendritic ditch structure (refer Table 5)
 
Where as in others (like in practice C it is specified in non acceptance category)
 
When a report specifies for weld IGC as Interdendritic ditch structure, is it acceptable?



--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...