[MW:587] Re: Annular bottom plates from API-650 Tanks

Gentlemen,
A word to the wise... You could find yourselves in a lot of trouble for copyright infringement, not only with the API but also Google.
As you are well aware, copyright exists in ALL API material: I advise you NEVER to post illegal copies of copyright material in a public chat room. I realise it was done with the best of intentions to help a colleague in need, but please find another way of communicating the information.
 
I'm posting this advice to help you and others stay out of trouble. We have no idea who is monitoring internet traffic! Unfortunately, today Big Brother undoubtedly IS watching us.
 
I'm in Scotland! These emails are read all around the world.
 
Regards to all,
Owen Jenkins.
 
 
 
----- Original Message -----
Sent: Thursday, February 21, 2008 8:58 AM
Subject: [MW:586] Re: Annular bottom plates from API-650 Tanks


I think you are missing the copy of API 650......!

A283 Gr.C comes under group I and the following part of API 650 is self explainatory.

5.5 ANNULAR BOTTOM PLATES
5.5.1 When the bottom shell course is designed using the allowable stress for materials in Group IV, IVA, V, or VI, butt-welded
annular bottom plates shall be used (see 5.1.5.6). When the bottom shell course is of a material in Group IV, IVA, V, or VI and the
maximum product stress (see 5.6.2.1) for the first shell course is less than or equal to 160 MPa (23,200 lbf/in.2) or the maximum
hydrostatic test stress (see 5.6.2.2) for the first shell course is less than or equal to 172 MPa (24,900 lbf/in.2), lap-welded bottom
plates (see 5.1.5.4) may be used in lieu of butt-welded annular bottom plates.

M.4.1 Tanks with diameters exceeding 30 m (100 ft) shall have butt-welded annular bottom plates (see 5.1.5.6).

5.1.5.6 Bottom Annular-Plate Joints
Bottom annular-plate radial joints shall be butt-welded in accordance with 5.1.5.5 and shall have complete penetration and complete
fusion. The backing strip, if used, shall be compatible for welding the annular plates together.

5.1.5.5 Butt-Welded Bottom Joints
Butt-welded bottom plates shall have their parallel edges prepared for butt welding with either square or V grooves. Butt-welds shall
be made using an appropriate weld joint configuration that yields a complete penetration weld. Typical permissible bottom buttwelds
without a backing strip are the same as those shown in Figure 5-1. The use of a backing strip at least 3 mm (1/8 in.) thick tack
welded to the underside of the plate is permitted. Butt-welds using a backing strip are shown in Figure 5-3A. If square grooves are
employed, the root openings shall not be less than 6 mm (1/4 in.). A metal spacer shall be used to maintain the root opening between
the adjoining plate edges unless the Manufacturer submits another method of butt-welding the bottom for the Purchaser's approval.
Three-plate joints in the tank bottom shall be at least 300 mm (12 in.) from each other and from the tank shell.



With regards,
Kannan Sundaram.



"saqib gul" <saqibgul@gmail.com>
Sent by: materials-welding@googlegroups.com

21/02/2008 07:49

Please respond to
materials-welding@googlegroups.com

To
materials-welding@googlegroups.com
cc
Subject
[MW:585] Annular bottom plates from API-650 Tanks





Can any body help me out that in which cases we use annular bottom plates for above ground storage tanks? Are there any recommendations in API-650 regarding the use of annular plates? Are the use of annular plates depends on the size of tanks? I am particularly talking about A-283 Gr.C Plates.
 
Regards
Saqib Gul
Design Engineer
Attock Refinery Limited
Pakistan


--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
-~----------~----~----~----~------~----~------~--~---

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...