Friday, February 29, 2008

[MW:634] Etch structure acceptance in IGC test per ASTM A262

ASTM A 262 Practice E does not specify anything about the acceptance of Interdendritic ditch structure (refer Table 5)

 

Where as in others (like in practice C it is specified in non acceptance category)

 

When a report specifies for weld IGC as Interdendritic ditch structure, is it acceptable?


--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:35686] HDPE WPS

Refer ASME SEC IX  There is separate chapter for Plastic welding . Based on that you have to prepare  Sent from my iPhone On 21 Jun 2025, at...