Skip to main content

[MW:619] RT after PWHT

Request to all members: Please use appropriate subject line!

 

What is your design code, Sec VIII div 1 is mandatory RT after PWHT only for Ferritic SS grades. But if I am the inspector may insist for NDT after PWHT since thick is high in your case, alternately you may propose UT after PWHT instead of RT.

 

 


From: Vijay Singh [mailto:vijays@tpc.ae]
Sent: Wednesday, February 27, 2008 10:34 AM
To: materials-welding@googlegroups.com
Subject: RE: 611] Re: ELEMENT WHICH GIVE LOW TEMP TOUGHNESS TO SA333 Gr.6

 

I need your inputs

 

SS 321 Pipe , 42 mm thickness , welded . radiography was performed after welding and report  cleared by TPI was OK with not a single repair advice on 224 mtrs…... ASTM allows radiography before PWHT , but client is insisting on radiography after PWHT . Is there any change in results if radiography is done after PWHT as compared to the radiography results before PWHT.

 

What is the logic for asking for radiography after PWHT if ASTM allow it.

 

rgds

 

Vijay

 

 


--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
-~----------~----~----~----~------~----~------~--~---

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

[MW:36169] Cold Bending Qualification

Dear Experts,  Can anyone share the inspection requirements or a qualification procedure for cold bending? Our client spec states only the requirements for induction bending and would like to know your opinion on the cold bend inspection requirements. The code of construction is B31.3, Max. 5D bends, A106 SS 316L.  Thanks in Advance. -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/1be61cc3-e9c9-4a5f-834d-e8485e248432n%40googlegroups.com .

[MW:30043] Weep hole

If weep hole is not provided in dummy pipe before welding What will happen??? -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/da251ee6-fa7f-4851-b876-cdb3834ae341%40googlegroups.com .