Hi,
 
Cannot possible to use the Same WPS.
 
May be you can write the Prequalified WPS for the 3G position ,
 
Or
 
You can qualify the WPS for the 3G position to qualify the welders
 
Or
 
You can go for the Production mock up
 
Regards,
 
Babu
Singapore
 
----- Original Message -----
Sent: Tuesday, June 08, 2010 12:48 PM
Subject: [MW:5437] Welder Qualification in 2G - 3G

Dear friend,
 
I have a query as below.
 
Our customer had establised a WPS/PQR  in 2G position - 16 mm thk plate.
 
They want qualification test for welders in 3G position (6mm Thk Plate), Can we allow the same?
 
Electrode: E7018
Coupen : IS 2062 Gr. B plate
Ref. Code : AWS D1.1
 
Regards,