[MW:35719] Regarding requalification of Procedure qualification required or not for when welding FCAW filler wire brand name change
We have having WPS with impact test at -29 Deg.c for FCAW process. as per ASME SEC-IX. As per engineering requirement Impact test required at -29Deg.c.
Now new filler wire brought having same SFA NO but different brand name from same manufacturer. Mechanical properties were same. Impact test carried out at -40 Deg.c as per MTC.
We need to qualify new PQR or Proceed with existing PQR.
Regards,
Shanmuga. --
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/97c89848-d5c1-4b58-ab03-66536ddb850an%40googlegroups.com.
Now new filler wire brought having same SFA NO but different brand name from same manufacturer. Mechanical properties were same. Impact test carried out at -40 Deg.c as per MTC.
We need to qualify new PQR or Proceed with existing PQR.
Regards,
Shanmuga. --
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/97c89848-d5c1-4b58-ab03-66536ddb850an%40googlegroups.com.