Re: [MW:35739] Bend Test and Tensile Test failed for ET45 Micro Welded Coupon

For welding ET 45 Micro (GX45NiCrSiNb35-45), the typical procedure involves using a nickel-based filler metal like UTPA 3545Nb 

(as Mr. Mahesh recommended) or its equivalent CEWELD 3545 Nb (both are classified under EN ISO 14343-A standards) and 

designed for welding Ni-Cr-Nb-Si based high-temperature cast alloys.  

Generally, no preheat or PWHT is required for ET 45 Micro, but it should be welded with controlled heat input and limited interpass 

temperature (monitored properly) around max 150°C. Preheat may be applied if welding thick sections or to reduce residual stress, 

but it must be confirmed with field testing. 

C Sridhar.

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------


On Sat, 26 Jul 2025 at 15:34, ROHAN SONI <sonirohan94@gmail.com> wrote:
Dear Team, 

I am working on a material called ET45 micro (GX45NiCrSiNb45-35 Material) 

Elongation is 3 to 5℅
Tensile stength -450 Mpa
Consumable- ERNICRMO-3 

Due to such lower Elongation material shows brittle fracture and immediately failed from HAZ. 

During tensile testing it is failed from Where it holds from base metal. 

Kindly provide the solution for this that how can i comply the PQR testing. 

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAMQ93h8E5kdWag0gJa6tyqzRzG6qg%3D1KZ%2B3d_bBd6sKnOR%2Bjkw%40mail.gmail.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAHo%3DYihv4SPsJFxZuLWwPJzprjqZ%2Bdguqrk-f4Au%3D07JvGH%2BDg%40mail.gmail.com.

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...