For SAW welding wire/flux classification as an sample for discussion
As per A 5.17 it is represented as F7P8-EH12K, this classification is given by the product manufacturer on the flux bag and is inline with the ASME Sec II Part C SFA 5.17
Where P is pwht and 8 is Minus 80 Deg F Impact test
I have a Procedure qualification which is Impact tested at Minus 50 Deg F, Qualified as per ASME Sec IX
as per QW 404.9
is it correct I write on my Procedure qualification record
F7P5-EH12K
Please advise above is correct, if not I would like to understand more on this what should be written and clarification to increase knowledge
-- https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/f81d62f2-1e20-456f-baee-0159e2ef3222n%40googlegroups.com.