Saturday, April 20, 2024

[MW:34895] ESAB Flux OK 10.92 vs OK 10.93 - Query ( URGENT )

Dear Welding experts,

For one of our Offshore Projects in Korea, we have a vessel of 304L material with Impact Test at -196 Deg C as per Project Spec.

So, to weld SAW , SFA 5.9 Class ER308L 4mm Dia,  we are going to use ESAB SeAH, a top brand in Korea.

I heard and mostly used the SAW 308L wire with OK Flux 10.92 for many SS vessel fabrication , because this Flux is of neutral type and the alloy element gives Cr during welding and got this message from the catalogue.

Metallurgically, What major difference will occur between OK 10.92 and OK 10.93 during multi run SAW welding on a test plate and Impact testing at -196 Deg C, Ferrite Test, Corrosion test etc., will be done in the lab.

Please advise me soon.

Regards,
Saravanan Sornam,
ANSAN-Si,
S.Korea


--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CALV1rk%2B3BHEB7opx1_KVS53J%3DfWTkY3yxs_3xOFm7%2BsbbB1EyQ%40mail.gmail.com.

No comments:

[MW:34920] Tubesheet Hole step

Hello Team, I have one question any tolerance given for tubesheet Hole step. Please do needful. Regards, AP  -- https://materials-...