Re: [MW:33806] Duplex, super duplex stainless steel repair

Dear Ganesh
what grade?, what type of failures (in NDE or in service?), any root cause analysis done.
Knowing the root cause and extent of damage is very important before attending repairs.

if you are considering these are as closure joints, then only Volumetric examination is permitted, otherwise check feasibility for in service testing

On Thu, 8 Dec 2022 at 13:22, Ganesh Muthurajan <qceng.mg@gmail.com> wrote:
Good morning sir, 

Now i working with duplex and super duplex , RO plant.

How to do the repairs in this material, for example we found two segment in 10 mm  in 14 inch pipe. 

Can we do partial repair, or fully cutout and reweld.  Any code reference advice to do full cutout, or partial.

Second case this plant was handed over to the Clint, during commissioning we found leakage, not only the butt joint, even in the branch connection, 

Aramco advise to do 100 %rt butt joint and branch.

Branch we can't do RT, placing a film is deficult.  What to do in this. 

Please advise me your experience and international, Aramco code reference.


Thank you

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAM0EmFJPK-9Z8w9M%3D0wje6%2Bd%2BH%2Bn_7-SZmhy7R2ksEv_SYEB3w%40mail.gmail.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CADxVubnMUK_U0EbNLjNjNceka_wcTxq9WvWEd_hLa%3D77ot7hfQ%40mail.gmail.com.

No comments:

[MW:34920] Tubesheet Hole step

Hello Team, I have one question any tolerance given for tubesheet Hole step. Please do needful. Regards, AP  -- https://materials-...