At @ 900-940 Deg C , the Carbon will react with Ti /Nb/Cb to form its carbides . This results into no Carbon or very less Carbon will be available to form Chromium Carbide which is detrimental to corrosion resistance.
Thanks and regards
Vishwas - IWE
International Welding Engineer
On Thursday, December 22, 2022 at 8:53:38 AM UTC+5:30 Prakash Hegde wrote:
Hi! FriendsWhy some of the client spec ask forStabilizing treatment (At lower temperature than solution annealing i.e. about 900C) of already solution annealed plate but not Welded SS componentsEspecially 304H,347,321RegardsHegde
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/4869cfea-8374-4bcf-9154-d224480f611bn%40googlegroups.com.