Wednesday, September 18, 2019

Re: [MW:30072] AWS D1.1

There is no restriction as above for any particular material. Also S355JR is unlisted material as per AWS D1. 1


-------- Original Message --------
Subject: [MW:30071] AWS D1.1
From: K K
To: Materials & Welding
CC:


Dear All,

Is there any restriction for material welding in position as per above mentioned code.
for one of our client is given comments for position for particular material.
For material S355JR#S355JR welding - Limited to F,H&V position. OH not allowed.

Please any one know in which clause they have mention we can't use  OH is not allowed.
Thanks and Regards
Kiran

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/f8d4b73e-ee57-4d29-afa1-d609f1162508%40googlegroups.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/-oc0twfydkdpf8pyg5l-5wpq9zyxbnjs-6hzj8j202739gw37merdbfss-8zz7lxqmgf10pq4ldk-ygd3bn-glz5bniuc1la1dcz7a7b3h4umhxwb130gk7q-f1nsf4850pcl6xuuh7915fup-3tw2xs.1568807935146%40email.android.com.

No comments:

[MW:34920] Tubesheet Hole step

Hello Team, I have one question any tolerance given for tubesheet Hole step. Please do needful. Regards, AP  -- https://materials-...