Saturday, September 28, 2019

[MW:30093] F‐No. 6.



Dear sirs,

kindly advise on the below query.....


 Deposited weld metal made using a bare rod not covered by an SFA Specification but which conforms to an analysis listed in Table QW-442 shall be considered to be classified as F‐No. 6.


 Regards
Raja 

No comments:

[MW:35614] Re: SS FILLER

dear , pl check A number and Gas composition use for ss cant be sutibale same % for duplex., u need to qualified with aditional testing of f...