Sunday, May 14, 2017

Principles and prevention of crevice corrosion

Introduction

Crevice corrosion is not unique to stainless steels. It can occur in other alloys including those of aluminium, titanium and copper.
It is a localized form of attack, where there is a breakdown of the surface passive layer, in crevices or on 'shielded' areas beneath surface deposits. Engineered or 'designed in' crevices can be set up at bolted and other joints, beneath flanges or between flanges and gaskets or other contact areas such as valve seats.

The mechanism of crevice corrosion

To be an effective corrosion site, the crevice must be wide enough to allow the corroding electrolyte in and then provide 'stagnant' conditions. Crevice corrosion can therefore be a concern where gaps are a few micrometers wide, but there are no absolute or critical dimensions for crevices, below which corrosion is certain.

As a corrosion mechanism, crevice attack is similar to pitting (i.e. free surface localized attack)

There is a distinction between the initiation and the propagation of crevice attack and there are a number of theories. For this short account the summary in John Sedriks' book has been reviewed. He assumes that there is some initial general corrosion in the passive state. The release of metal ions (M+) at the anode is balanced by a reaction at a nearby cathodic site, which involves using up oxygen from the surroundings. In a crevice oxygen can soon be used up and if the conditions are stagnant enough, replenishment of the oxygen to the crevice from the bulk solution is stifled. If this reaction continues outside the crevice it can support a corrosion cell where the metal ions continue to be liberated in the anodic crevice. This results in a build up of the positively charged metal ions in the crevice. The mechanism then moves to a stage that involves the familiar affects of chloride and pH on crevice (and pitting) corrosion.
The negatively charged chloride ion (Cl-) is very mobile and so if present in the bulk solution outside the crevice, easily migrates into the narrow crevice under the attraction of the positively charge metal ions (M+). The metal chloride (usually involving chromium) formed in the crevice then reacts with water to form hydrochloric acid. The build up of acid reduces the pH until a 'depassivation pH' is reached where the passive film is breached locally in the crevice so that the 'pitting' attack can then continue. 
Once depassivated the attack can progress rapidly and is self sustaining, especially if there is a ready supply of chloride ions from the bulk solution.

Alloy selection to avoid crevice corrosion

The stability of the passive layer on stainless steels is promoted by chromium and supported by nickel. Although the chromium metal ion supports the anodic reactions in crevice corrosion more than iron or nickel, alloys with increasing chromium are better in resisting crevice corrosion. For given chromium level, austenitic stainless steels seem to resist attack better then the lower nickel ferritic types. Molybdenum and nitrogen have a very marked affect on increasing resistance, molybdenum assisting by arresting the rate of attack once depassivation has occurred and rapid attack is usually the next stage.

As a general rule stainless steels such as the 6% molybdenum austenitics and superduplex grades can be expected to give the best crevice corrosion attack resistance. As a guide some common stainless steels, rated in decreasing resistance to crevice corrosion, follows: -

 

1.4547 and 1.4529 (6% Mo austenitic) plus 1.4501 1.4410 1.4507 (superduplex)

1.4462 (2205)

1.4539 (904L)

1.4401/1.4436 (316)

1.4301 (304)

1.4016 (430)

 

.

Avoiding crevices in design

Keep junction points as wide open as possible.
Avoid 'designed in crevices' that can be formed in flanged or bolted joints. Both metal / metal or metal / non-metal contacts can result in attack sites and so the use of insulating gaskets will not prevent crevice corrosion. Good fit-up and adhesion of non-metal joints or gaskets is important to avoid crevices being formed between the two materials.

Avoiding crevices during fabrication

Crevices can be formed during fabrication at welded joints where full bead penetration has not been achieved. Full root penetration is essential with as rounded and smooth a bead as possible, with no undercut in the internal bead to parent metal area.

Avoiding crevices during operation

Build up of scale or settlement in tanks can result in crevice (shielding) corrosion. Steps to prevent this or introducing a routine cleaning / maintenance program, where some build up is unavoidable, is worth considering.

 

 

 

Source: http://www.bssa.org.uk/

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...