If you are referring to ASME B31.3, refer para 328.4.2 and 328.4.3, generally it is permitted as stated in the applicable WPS. However in case of HP piping it is 1.5mm (1/16”), that’s why most of the WPS states as 1.5 or 1.6mm as permitted misalignment.
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Ayhan GEDUK
Sent: Tuesday, April 14, 2009 1:49 AM
To: materials-welding@googlegroups.com
Subject: [MW:1935] Re: Variation in Pipe thickness
Dear Vivek, I think you will never get proper answer untill your working code.
|
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---