[MW:1384] Re: WPS qualification

Please read and interpret QW403.5 para after (c) in ASME Sect IX.If you have separately qualified procedures for P8 Gr1 to P8Gr1 and P8Gr2 to P8Gr2 and if you do not change the essential variables indicated in these qualification then combined specification gets qualified
Regards
Aarpee

On Wed, Dec 3, 2008 at 1:45 PM, SHRIRAM PURANIK <stpuranik@gmail.com> wrote:
Can any body clarify for SA 240 TP 310S (P8 Gr. 2) + SA 240 TP321 (P8 Gr.1)  WPS to be separately qualified if I have separate qualified WPS and what filler wire to be used.
 
Regards,
 
S T Puranik

--