hi, Mr denaouda,
you can refer procedure provided and the last pl contact pipe mfg for final pressure and holding.(i think who is mfg CPI,oman ?)
there is two one test is strength test of 4 hr and second is a leak test of 24 hr at design or 1.1 design.
regards,
Siraj.
On Wednesday, August 3, 2022 at 11:21:29 AM UTC+3 Benaouda Mezrar wrote:
hi expertcould anyone have a procedure for HYDROTEST pipeline GREthanks