Tuesday, August 2, 2022

[MW:33345] HydroTest Pressure recorder and chart- Range selection

Dear Sirs,

In case of Hydrotest, as per ASME Sec VIII Div-1, UG-102 (b), 
only for the dial indicating gauges,
the range has been given such as 1.5 to 4 times of the test pressure, when selecting the pressure GAGEs.

But, for Pressure Test Recorder with the chart, is there any requirement in either ASME CODE Or any other project spec, given the range of selection of Pressure recorder like the dial indicating gages for the test pressure.

Please share your views.

Regards,
Saravanan Sornam,
Korea.




--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CALV1rkKzJxE7srjkxNdgG%2BaJJYM_gYLXfq1U8OAwuKG_BXrRNw%40mail.gmail.com.

No comments:

[MW:35614] Re: SS FILLER

dear , pl check A number and Gas composition use for ss cant be sutibale same % for duplex., u need to qualified with aditional testing of f...