Corrosion of Stainless Steels in Supply (Drinking) and Waste (Sewage) Water Systems

Introduction

In pure water at normal (ambient) temperatures, stainless steels can be considered "inert". Except for chemically purified waters there are various levels of anions, including chlorides, which can be aggressive to stainless steels under certain circumstances. General corrosion over large areas of the surface is not usually encountered on stainless steels, due to formation and maintenance of an inert "passive" surface layer, but localised corrosion can occur due to the breakdown of the passive layer by chlorides at discrete sites.

 

 There are three main types of localised corrosion mechanisms that can affect stainless steels :

 - Pitting corrosion

Crevice corrosion

Stress corrosion cracking

• Pitting corrosion tends to be associated with free surfaces of stainless steel. This form of localised attack can be severe and lead to rapid perforation of thin sheets or tubes. Attack is concentrated at microscopic defects in the protective passive oxide film (for example at the site of inclusions at the surface of the steel).

• Crevice corrosion is a form of attack based on "engineering" sites rather than the "metallurgical" sites responsible for pitting. It tends to occur more readily at sharp changes in section or shielded areas and so is potentially more hazardous.

• Stress corrosion cracking normally occurs at temperatures over 60°C This condition must be accompanied by tensile stresses and chlorides to enable this form of attack.

 

The main factors that promote corrosion in waters are:

- Chloride level

Temperature

Oxygen level

Water flow rates

Presence of bacterial oxidants

 

Chloride levels A limit of 200 ppm (mg/litre) maximum has been set for chlorides in drinking (potable) waters by the EU. Levels in the UK tend to be below 100ppm and at "ambient" UK water supply storage and distribution temperatures these chloride levels should not be a crevice or pitting corrosion hazard to stainless steel types 304 (1.4301 / 1.4307) or 316 (1.4401 / 1.4404), which are commonly used in these applications.

The accepted view is that crevice corrosion is rare below:

 - 200 ppm for 304 (1.4301 / 1.4307)

1000 ppm for 316 (1.4401 / 1.4404)

In situations where exposure times are short and there is some "rinsing", as in the case of coastal sewage outfall installations, where high tide chloride levels can reach 1000- 2000ppm levels for short periods of time, the 316 (1.4401 / 1.4404) types can be a satisfactory and economic choice. Well maintained water flow rates and oxygen levels will help these steels maintain their corrosion resistance in these applications.

Care must be taken in design however to ensure that chloride levels do not increase by evaporation at liquid surfaces or in splash zones.

Chloride concentration under water scales can also be a corrosion hazard.

Between 1000 and 3600ppm duplex grade 1.4462 (2205) can be considered. Above these levels "super duplex" grades, such as 1.4410 (SAF2507) or 1.4501 (Zeron 100) or super-austenitics, such as 1.4547(254SMO) or 1.4529(1925hMo) are appropriate. These can also be used in seawater applications, where chloride levels are of the order of 26,000ppm.

 

Temperature The risk of crevice & pitting corrosion attack increases with temperature. At the temperatures and chloride levels normally encountered in water supply & treatment applications, these forms of attack are not usually relevant.

These corrosion mechanisms, along with stress corrosion cracking, are only usually of concern in applications such as water boilers and heating systems, particularly in situations where chlorides can concentrate. Lower temperature environments such as swimming pool building atmospheres, which are particularly aggressive to stainless steels, can also be a SCC hazard concern.

 

Source: http://www.bssa.org.uk/

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

Heat tint (temper) colours on stainless steel surfaces heated in air // Heat tint

Introduction The colour formed when stainless steel is heated, either in a furnace application or in the heat affected zone of welds, is dependent on several factors that are related to the oxidation resistance of the steel. The heat tint or temper colour formed is caused by the progressive thickening of the surface oxide layer and so, as temperature is increased, the colours change.   Oxidation resistance of stainless steels However, there are several factors that affect the degree of colour change and so there is no a single table of colour and temperature that represents all cases. The colours formed can only be used as an indication of the temperature to which the steel has been heated. Factors affecting the heat tint colours formed Steel composition The chromium content is the most important single factor affecting oxidation resistance. The higher the chromium, the more heat resistant the steel and so the development of the heat tint colou...

Re: [MW:10788] ON PLOT PIPING & OFF PLOT PIPING

Piping systems involved for the flow lines and gathering lines from the well head isolation valve to the production facility or processing plant isolation valve are determined as OFF PLOT. ON PLOT defines piping system in the processing plant and production platform. ANSI/ASME B31.4 applies for off plot piping system. B31.4 allows the use of either API 1104 or ASME section IX (as appropriate). However, occasionally, a very small system such as piping within 500 feet of a processing plant (some client also said 400 feet) may be declared B31.3 rather than B31.4. When B31.3 is invoked, only ASME Section IX is used. before you decide which code to use for welding procedure and/or welder qualification for pipe welding, you have to know the design and construction code applicable to the system. Please read far enough into scope and diagram illustrating the application of either B31.3 and B31.4 hope this helps rgds 2011/4/21 pradip kumar sil < pradipsil@gmail.com > Dear all, ...