Saturday, July 23, 2011

Re: [MW:11866] Calculation for root gap according to tihckness of pipe

dear abhishek ,

Root gap you can refer from an wps .Generally as per standard the root gap is 3-4 mm max to have full penetration at joint. 
if it is different thickness so you has to go for internal bevelling near id so your thickness get matched .

regards

dinesh

On Fri, Jul 22, 2011 at 2:17 PM, abhishek ojha <abhishekojha_iu@yahoo.co.in> wrote:

Dear Expert,

Kindly guide me how to calculate root gap according tihckness of pipe of different /same dia.(different tickness but same dia)


Thanks & Regards,

 

Abhishek Ojha


 Engineer- Construction 


cid:image001.gif@01CA0B94.B49995B0

 

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...