Dear All
our contractor have procured E7018-1,that manufacture recommended DCEP/AC.but they use DCEN in PQR(accepted) and production.
according to this has conflict with AWS A5.01 and manufacture's recommendation. is it true or not?
regards
Refer ASME SEC IX There is separate chapter for Plastic welding . Based on that you have to prepare Sent from my iPhone On 21 Jun 2025, at...
No comments:
Post a Comment