restricted at 600-620C but incase of PWHt at 690 and above for overlay or
restoration of cladding you have to use inconel weld i.e. use ENiCrFe2 or
ENiCrfe3 and for Tig process use ER NiCr3 This will definitely serve your
purpose w/o failure in bend
Hegde p.B.
09714714803
-----Original Message-----
From: materials-welding@googlegroups.com
[mailto:materials-welding@googlegroups.com] On Behalf Of av-ssg
Sent: Tuesday, June 02, 2009 10:13 AM
To: Materials & Welding
Subject: [MW:2298] Cr. cabide exothemic in SS cladding
When you need TIG clad welding on A387-11-2 with ER309L rod and PWHT
is requird after welding in 690 dgree (for service resons),fracture
happend in bend test.becuse the Cr. cabide exothemic.
In this case how can slove this problem?
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---