[MW:1927] Re: 1224] RE: 1220] Re: usage of phased array probes in TOFD

Dear Raghavendra,

Attached abstracts may be helpful to you!

When used in conjunction, these two techniques allow for higher probability of detection (POD), normally requiring a great amount of time and/or experienced UT inspectors.


On Mon, Oct 20, 2008 at 4:06 PM, CKPurohit <ck@knm-group.com> wrote:

Dear Raghvendra,

 

May be correction required in your question. Using PA probes along with TOFD probes (simultaneously both method on one joint) - If that is the case Answer is yes.

 

FYI : TOFD probes are having normal connectors (lemo) where PA probes are coming with the multi point connector (to take care of each crystal energizing)

 

I hope your doubt might have cleared.

 

Regards.

CK

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of Rohit Bafna
Sent: Isnin, 20 Okt 08 05:00 pm
To: materials-welding@googlegroups.com
Cc: 'RAGHAVENDRA PEMMARAJU'
Subject: [MW:1224] RE: 1220] Re: usage of phased array probes in TOFD

 

Dear all,

 

How on earth can you do ToFD by attaching Phased Array probes. Totally not possible. These are two different techniques. I agree with SSK.

 

Regards,

Rohit Bafna

Director - Global Sales

 

------------------------------------------

TCR Engineering Services (India)
TCR Arabia (KSA), TCR Kuwait

TCR World Inc. (USA)

USA Tel: +1-240-505-0739

India Tel: +91-983-353-0400

www.tcreng.com
Material Testing | Consulting | Inspection | NDT Services

-------------------------------------------

 

From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of SENTHILKUMAR SWAMINATHAN
Sent: Saturday, October 18, 2008 1:16 AM
To: materials-welding@googlegroups.com
Cc: RAGHAVENDRA PEMMARAJU
Subject: [MW:1220] Re: usage of phased array probes in TOFD

 

PRV,

 

This is not possible as per me. Better go to www.ndt.net, write in technical disscussion forum some can give you some inputs. That one is purely NDT site.

 

Regards,

SSK 

--- On Sat, 11/10/08, raghavendra pemmaraju <pemma_raghav@yahoo.com> wrote:

From: raghavendra pemmaraju <pemma_raghav@yahoo.com>
Subject: [MW:1210] usage of phased array probes in TOFD
To: "materials-welding@googlegroups.com" <materials-welding@googlegroups.com>
Date: Saturday, 11 October, 2008, 9:35 PM

Whether any one belonging to this group used the above combination for performing TOFD by using Phased Array probe. If so pl.share the experience and procedure.

 

regards,

 

Raghavendra

 




Send free SMS to your Friends on Mobile from your Yahoo! Messenger. Download Now! http://messenger.yahoo.com/download.ph


 


***DISCLAIMER NOTICE ***
"This e-mail and any files transmitted with it is confidential and is intended only for the use of the recepient(s) named above.
If you are not the intended recipient, any review, retransmission, dissemination, distribution, printing, copying or use the information contained in this message or any part thereof in other manner is strictly prohibited.
If you receive this e-mail in error, please notify the sender immediately by return e-mail and delete the e-mail and any of its attachments.
Any personal views or opinions expressed by the sender shall be understood as neither given nor endorsed by KNM or any of the companies within the Group."




--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...