Gasket selection mainly depend on Temperature and Pressure of the media, Corrosive nature and Criticality of the application
Since you are using 316 in place of A105, u may use the similar combination of gasket, studs used for a CS#CS joint in the same process stream (since design conditions are same), unless you have contractual requirements if any.
From: Zameer Mohammed [mailto:dreamthinkwork@gmail.com]
Sent: Tuesday, May 27, 2008 10:47 AM
To:
Subject: SS & CS Flanges
Dear Friends,
We have 2 mating flanges, one is SS316 and another is A105. Can I connect SS Flange with CS Flange? In this case, what type of Gaskets, Stud Bolts & Nuts we can use?
For all other CS flanges we are using spiral wound gaskets.
Thank you,
Regards,
Sabir
--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---