Tuesday, April 8, 2008

[MW:709] RE: 708] re radiography bunker

It depends on various factors, what type of bunker you want built. (i.e
with concrete, sand bags, or steel etc.),

TVT value for each of the above are different, hence thickness of wall
may vary dpend on the max Ci of source you use,

Dimensions of the bunker you can slelect depend on the max dimensions of
the item you want to radiograph.
Assuming Safe radiation for human being@ 0.0075 mSv / hr, for Ir192
100Ci source you may need 50cm thk wall of concrete (RCC) aprx..


-----Original Message-----
From: materials-welding@googlegroups.com
[mailto:materials-welding@googlegroups.com] On Behalf Of gajjalla surya
prakash
Sent: Tuesday, April 08, 2008 12:14 PM
To: materials-welding@googlegroups.com
Subject: [MW:708] re radiography


dear all,

can any one give the details of radiography buncker room dimensions
for carrying out radiography using ir 192.

surya prakash gajjalla,
ASSOCIATED ENGINEERING SERVICES.

--~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---