consumables, other wise use 309 for welding this dissimilar joint.
On Apr 6, 11:29 pm, "Zameer Mohammed" <dreamthinkw...@gmail.com>
wrote:
> Hi...
>
> We are replacing an old Flare Tip with a new velocity seal type Flare Tip.
> The Flare Tip vendor is giving the Flare Tip with a Flanged end and the
> mating Flange is supplied ship lose with the Flare Tip.
>
> I want to know something about the material compatibility of the Flare Tip
> Flange and the existing Flare Stack, upon which the mating Flanges will be
> welded.
>
> The Flanges provided by the vendor is *SS316*.
>
> The Flare Stacks are made of *API 5L or Fe42B (SA516 Gr.70)* for 36'' and
> 42''
>
> Flare Stack for 24'' is *A240 Tp316*
>
> In this case, can I weld the SS316 with theses material?
>
> Kindly advice me on this
>
> Thank you,
>
> Regards,
>
> Sabir
--~--~---------~--~----~------------~-------~--~----~