Skip to main content

[MW:750] HI I AM IN USA


Dear All,

 

Hi ,it is very glad to tell you all that our company has been authorised by AWS ( American society of welding) to conduct CWI certified welding and certiifcation programme.

 

I have been invited by AWS MIAMI HQ to take part in the international conferance here.

 

I am at present in NJ NEWJERSEY

 

HOTAL HOWARD JOHNSON EXPRESS IN

1025 RT 22 WEST NORTH PLAINFIELD  NJ 07060 PHONE 09087536500 

 

I will leave NJ on 27th morning.

 

I will remain in MIAMI -FLORIDA on 27th april night to Ist May morning .

 

My address at Miami is Hotel Airport Mariott Miami.

 

If any body is nearby there plz contact.

 

Plz circulate the brouchere to all concerned.

 


 

FOR DASH INSPECTORATE

U.G.DAS
DIRECTOR
804,BLUE DIAMOND COMPLEX,
NEAR FATEHGUNJ PETROL PUMP
FATEHGUNJ-BARODA GUJARAT-INDIA-02
9327201999,0265 2700454,
MOBILE 09825164743


--- On Sun, 20/4/08, Jignesh Patel <nacemail@gmail.com> wrote:
From: Jignesh Patel <nacemail@gmail.com>
Subject: [MW:723] AET type exchanger test ring
To: materials-welding@googlegroups.com
Date: Sunday, 20 April, 2008, 9:16 PM

Dear Friends,

 

I have seen few heat exchangers on this forum. I am an end user of heat exchangers in refinery. My query is related to test rings of exchangers.

 

One of our new units has AET type exchangers [pull through type]. These exchangers have a floating tubesheet [FTS] with bolt holes and the floating head cover [FHC] is directly bolted to the floating tubesheet. The problem with this is that we can't carry out shell test using a conventional test ring due to several bolt holes on the floating tubesheet. Conventional AES exchangers have backing rings pressing the FHC against the FTS.

 

I checked TEMA website and it says, test rings for such exchangers are possible and the bolt holes in the tubesheet need to be temporarily plugged. It also says refer to 4.13 (3) of TEMA. Unfortunately we don't have the latest edition of TEMA.

 

Does any one have experience with test rings [for shell test] for AET type exchangers? I would appreciate a generic drawing / scheme showing how to carry  out shell test of such exchangers.

 

Thanks in advance.

 

Thanks and regards,

 

Jignesh

Kuwait

 

For your virus protection, any attachments should be considered uncontrolled unless they are identified in the text. The sender does not accept liability for any virus introduced by this email or any attachment.

 



Best Jokes, Best Friends, Best Food. Get all this and more on Best of Yahoo! Groups. --~--~---------~--~----~------------~-------~--~----~
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
-~----------~----~----~----~------~----~------~--~---

Comments

Popular posts from this blog

Materails FAQs

Q: What are equivalents for standard Q 235 B (and Q 235 A) for U-channels? (asked by: boris.vielhaber@vait.com) A: DIN Nr. = 2393 T.2, 2394 T.2, EN 10025 W. Nr. DIN 17007 = 1.0038 Design DIN 17006 = RSt 37-2, S235JRG2 (Fe 360 B) Q: What is St DIN 2391 BK material? (asked by: dmcandrews@automaticstamp.com) A: Precision steel tubes, cold-finished/hard. Q: What is C.D.W. Boiler Tube? (asked by: montydude123@yahoo.com) A: Cold Drawn Welded Boiler Tube. Q: WHAT IS W.Nr. 1.4301? PLS TELL US IN EASY LANGUAGUE (asked...

[MW:36169] Cold Bending Qualification

Dear Experts,  Can anyone share the inspection requirements or a qualification procedure for cold bending? Our client spec states only the requirements for induction bending and would like to know your opinion on the cold bend inspection requirements. The code of construction is B31.3, Max. 5D bends, A106 SS 316L.  Thanks in Advance. -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion visit https://groups.google.com/d/msgid/materials-welding/1be61cc3-e9c9-4a5f-834d-e8485e248432n%40googlegroups.com .

[MW:30043] Weep hole

If weep hole is not provided in dummy pipe before welding What will happen??? -- https://materials-welding.blogspot.com/ https://www.linkedin.com/groups/122787 --- You received this message because you are subscribed to the Google Groups "Materials & Welding" group. To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com . To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/da251ee6-fa7f-4851-b876-cdb3834ae341%40googlegroups.com .