Hi
For all your Question, Refer Table 4.11 of AWS D1.1. for answers which is self explanatory
Thanks and Regards
Rameshkannan Devaraj
"What you have learned is a mere handful; What you haven't learned is the size of the world – Avvaiyar"
On Thu, Sep 27, 2018 at 5:04 PM Somnath Ashtakar <s.ashtakar@gmail.com> wrote:
Dear All,
I have to re-qualify the welders as per AWS D1.1 but I have some
quires. Please help me to resolve the same.
1) What should be the test piece thickness for re qualification ? Our
previous thickness was 25 mm. ( As AWS shows option of 10 mm thk test
plate which will qualify any production welding thickness )
2) Do I need to go for mechanical testing or only radiography is sufficient?
3) What will be the qualification range after successful qualification?
Regards,
Somnath Ashtakar
8668674172
--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
Visit this group at https://groups.google.com/group/materials-welding.
For more options, visit https://groups.google.com/d/optout.
No comments:
Post a Comment