Thanks for sharing this interesting issue.
On Thursday, October 4, 2018 at 5:14:43 AM UTC+3, RAJESH KUMAR wrote:
-- as per my understanding you dont need to qualify new PQR if both meet the CVN requirements. As we see we are inline with same F no, same A no. although different filler wire specification with change is supplementary designation.
As per QW 404.12 and 404.33, you can just issue a new WPS based on the PQR with new designation.
Hope it will help.
Thanks & regards
Sandeep Kumar
On Thursday, October 4, 2018 at 5:14:43 AM UTC+3, RAJESH KUMAR wrote:
Dear Team,For our PQR qualification ( Done in 2018) to flux coared wire for carbon steel,we use the wire clasified SFA/AWS A5.20 E71T-1C/1M/9C9M.Today we received from our supplier wire classified SFA A5.36 E 71 T-1C 1A2-CS1.The classification is different,so we have to issue new PQR qualification required?Thanks & RegardsRajesh kumar055-5251449Sharjah