Are the bonders qualified as per code? In gre the test coupon is subjected to burst test to qualify bonder.
Prior HT check method of statement & HT procedure should include holding time, it shall be min 2 hrs @ 1.5 times n over 1.25 times for next 2 hrs / upto 24 hrs as in gre u can find seepage/ sweating at the joint n again it depends on test location n owner requirements. There may not be a deflection test post fabrication for gre
Cheers,
Srinivas
NKOM-Qatar
Sent from my iPhone 4
Sent from my iPhone 4
--
Dear experts,Kindly share your experiences of above test. What is deflection test and when is it performed? I am witnessing GRE piping installation and what are the documents required prior to test? Is it performed before hydro test or after? How do we accept incase of deviations? Should I insist to provide method of statement from the contractor?RegardsIlangkumaran
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.