Dear All,
Quoted below is the ASME Section VIII Div 1 requirement per UW 15 (b) (1):
(b) Strength calculations for nozzle attachment welds for pressure loading are not required for the following:
(1) Figure UW-16.1 sketches (a), (b), (c), (d), (e), (f-1), (f-2), (f-3), (f-4), (g), (x-1), (y-1), and (z-1), and all the sketches in Figs. UHT-18.1 and UHT-18.2;
In accordance with above almost all nozzle weld attachments are excluded from strength calculations. This appears to be contradicting with UG-41 requirements.
Can anyone please clarify?
Regards,
Limesh
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.