Monday, May 30, 2011

Re: [MW:11208] Renewal of Welder Qualification

Dear Limesh,
 
Just see clause 452.3 in ASME Sec.IX, there are Diameter restrictions, you have qualified your welder in 1 1/2 " Pipe means he falls in 1"(25mm) to 2 7/8"(73mm) restriction, which says Welder can weld from 1" to unlimited, but now for his renewal you are supporting 8" pipe, So asthetically it is not possible, he may fall in over 2 7/8" ( ie 73mm to unlimited), So better to show RTs of 1 1/2" or less than 2 7/8" Pipe . So that he can regain his qualification subject to his contuity record.

On Sat, May 28, 2011 at 6:29 PM, limesh M <limesh78@gmail.com> wrote:
Dear All,

Welder Qualification Code: ASME BPV SEC IX

I have a qualified welder with following diameter range.

1.1/2'' and above


Now his qualification is going to expire and I would like to renew it by showing supporting radiography reports.

Is it possible to renew the above qualification by showing the radiography report of an 8" diameter pipe?


Regards,

Limesh 


--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding+unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.

No comments:

Re: [MW:34913] Filler wire

E71T-1C  is Charpy Impact tested at -20degC E71T-1CJ is Charpy impact tested at -40degC. AWS Classification for FCAW is only a supplementary...