RE: [MW:6094] Flux to be used in SAW with PWHT

what you PQR states , if it is qualified with PWHT and CVN impact (if required), rewrite the WPS/PQR with F7P8. else qualify new PQR with PWHT using same combination used on production
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of prashant pansare
Sent: Friday, July 23, 2010 11:04 AM
To: mat wel
Cc: par kat; roj abra; sol grea
Subject: [MW:6093] Flux to be used in SAW with PWHT

Dear all,
My vendor is using WPS as follows:
Process - FCAW + SAW
Base Metal - S355 K2G3/ API 2H /2W GR 50
Thickness - 50 mm & above
Wire for FCAW - E71T-1
Wire for SAW - EH 12K & Flux - F 7A8
Preheat Temp.- 100 to 125 deg.C
PWHT  Temp. - 500 to 520 deg.C
As per
ASME Sec - II C Flux to be used shall be F 7P8 ( A denotes- as weld conditions &
P denotes for PWHT)                           
As  WPS includes PWHT Flux shall be used F 7P8.
Pl. guide me, weather flux used by the vendor is acceptable & if not what is to be done for the weld joints,those have been welded till date.  