Dear Mr Nilesh,
You should have given this info in the very first mail, which will stop all assumptions/guessing. still i don't understand why do you want purge a plate# plate joint? if you can't explain in a mail always advisable to attach a simple sketch. after all drawing is the engineers language.
We like answering questions for people who have demonstrated they canlearn from the answers.
Prepare your question. Think it through. Hasty-sounding questions get hasty answers or none at all. The more you do to demonstrate that having put thought and effort into solving your problem before seeking help, the more likely you are to actually get help.
Never assume you are entitled to an answer. You are not; you aren't, after all, paying for the service. You will earn an answer, if you earn it, by asking a substantial, interesting, and thought-provoking question - one that implicitly contributes to the experience of the community rather than merely passively demanding knowledge from others.
Hi, all there all possibility you have mention above butJoint - Plate to plate ( SA 240 Type 304 )Thickness- 6 mmType of Joint- ' V ' ButtBacking gas- ArgoanProcess - GTAWFiller wire - ER 308 L ( 2.5 mm )Root Gap - 2-3 mmBut as I have increase the backing gas to 12-14 lpm the weld become normal is it due to improper sealing of backing gas.NileshOn Fri, Jul 16, 2010 at 11:50 PM, Morin, Darcy (Bantrel Constructors) <MorinD@bantrelconstructors.com> wrote:
Possibly, you may have some surface contaminants on the filler wire or the parent material which are reacting to the heat of the welding process.Does your welder have clean gloves? Are the filler wires being individually cleaned with alcohol wipes?Was your bevelled end prepared with a machine which uses a cutting fluid? The inner walls of a GTAW joint should be ground clean of oxides and cutting residue 50 mm from the root face. The inner surface should be shiny after this cleaning/grinding.You may want to periodically check the purity of your purge before and during welding. It should be completely free of Oxygen... pure Argon.Good luck,Darcy Morin
From: materials-welding@googlegroups.com [mailto:materials-welding@googlegroups.com] On Behalf Of shamesh Lotlikar
Sent: July 15, 2010 10:17 PMSubject: Re: [MW:5993] Problem wk\hile root runHieee Pankaj,
Kindly check the argon gas purity and also check the purging is sealed properly or there is any leakage and air is entrapping inside. kindly check what is parent material , and welding consumable if the consumable is right for parent material. check all those parameters.
regards
shamesh lotlikar
welding consultant
From: pankaj abhang <pankaj.abhang1@gmail.com>
To: materials-welding@googlegroups.com
Sent: Fri, July 16, 2010 9:29:09 AM
Subject: Re: [MW:5992] Problem wk\hile root run
Check your fillerwire grade if GTAW if ok then chek its chemistry.I think this problem is with your filler wire.PANKAJOn Wed, Jul 14, 2010 at 6:27 PM, waman nilesh <wamannp@gmail.com> wrote:
I have problem while doing root run the weld get black from backside as we have maintain the backing 10 lpm & Shielding 12 lpm as per WPS.Can anybody tell me the reason & how to avid it.Nilesh--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.
No comments: