For Porosity, I let to know, Acceptance criteria is Appendix 4 ASME 8
div 1,
In that, 4.2 - b, c, d, f, & h. & Table 4-1 is there,
They are given as b) relevant indications
c) Maximum size for rounded indications
f) Charts.
and Table 4-1.
This is confusing, What we have to refer for a porosity in 6 inch weld
film
and in table 4-1, they given as Maximum Size of Acceptable rounded
indications & Maximum size of Non relevant Indications. What they are
said in the table.
Pl clear about that....
and for example weld thick is 12mm, wat's the accepatance limits.?
--
To post to this group, send email to materials-welding@googlegroups.com
To unsubscribe from this group, send email to materials-welding-unsubscribe@googlegroups.com
For more options, visit this group's bolg at http://materials-welding.blogspot.com/
The views expressed/exchnaged in this group are members personel views and meant for educational purposes only, Users must take their own decisions w.r.t. applicable code/standard/contract documents.