Friday, June 6, 2025

Re: [MW:35639] HARDNESS TEST

The standards referenced in API 6A are all for Brinell hardness testing
Δρ. Γεώργιος Διλιντάς
Ηπείρου 5 , Μελίσσια - 15127
Αεροναυπηγος Μηχανικός - Μελος ΤΕΕ 55018
Τηλ +30 210 8100578, +30 6944 646 204

Dr. Georgios Dilintas,
Dipl. Ing. In Aeronautic and Space Engineering
Ph.D in Mechanics of Solids - Computational Mechanics
A.I.S, A.N.I,  Lead Auditor
Welding, Stress Analysis, Corrosion, QA/QC, Failure Analysis, Risk Analysis


Στις Παρ 23 Μαΐ 2025 στις 8:09 μ.μ., ο/η Deerendra Karanth <dkaranths@gmail.com> έγραψε:
Sir, 

Use Brinell or Rockwell C as per the heat treatment and material type.The test location, frequency, and acceptance criteria must comply with API 6A PSL level (usually PSL 2/3) and material class (AA, BB, CC...).

BR 
Deerendra

On Fri, 23 May, 2025, 18:12 Elavarasan Mech, <elavarasan1861994@gmail.com> wrote:
Dear all
 
API6A FLANGE which hardness method recommended please guide me
Regard 
ELAVARASAN 

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAJ9L4ykHf%3D_jc7zpJqgC1GYN4UkJ_aMLroy0YsnLNY2TO5oCNQ%40mail.gmail.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAG0nF9GT77wWr0VUnaNkf4e8-oc%3D88j5Ahvp2mzjmasDofZSHg%40mail.gmail.com.

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion visit https://groups.google.com/d/msgid/materials-welding/CAPOi40D0BSn2YEKk86WQ0uXucFcSA7uyrMZxY-k7xj0G0-m%2B5A%40mail.gmail.com.

No comments:

[MW:35668] Selection of Filler/Electrode.

Dear Gentlemen, Kindly advise me as we have tube to tubesheet joint. Tube moc is incoloy 800 And tubesheet moc is F53 SDSS (Super duplex sta...