No, shall be assigned as UNLISTED material EEMUA 144 UNSC7060X 90/10 CuNi. which is not assigned in ASME Sec IX.
Therefore the subject welding procedure cannot be qualified for material P34 as per Sec IX clause 403.11, which is an essential variable.
On Sun, 17 Mar 2024 at 10:48, thulaib arakkal <thulaibwelding@gmail.com> wrote:
Dear All,--Can we assign P number 34 to EEMUA 144 UNSC7060X 90/10 CuNi.Regards,Thulaib