Saturday, March 30, 2024

[MW:34834] ASTM A 262 Practice C IGC test for Incoloy 825 material

Dear All,

In ASTM G28 test methods, under test time duration in clause 3, for Alloy N08825, a note is given as " While the ferric sulfate-sulfuric acid test does detect susceptibility to intergranular corrosion in Alloy N08825, the boiling 65 % nitric acid test, Practices A262, Practice C, for detecting susceptibility to intergranular corrosion in stainless steels is more sensitive and should be used if the intended service is nitric acid". Please refer to the attached picture.

1. Does this means only ASTM A 262 Practice C is enough and no need for ASTM G28 method for Incoloy 825 materials under nitric acid services?.
2. Also The Huey test (method C) is only for molybdenum-free grades, such as 304L, as alloys with molybdenum show high rates of attack in this test. But Incoloy 825 contains Molybdenum, So how can we use this test method for Incoloy 825.

Regards,

Thulaib Hussain

--
https://materials-welding.blogspot.com/
https://www.linkedin.com/groups/122787
---
You received this message because you are subscribed to the Google Groups "Materials & Welding" group.
To unsubscribe from this group and stop receiving emails from it, send an email to materials-welding+unsubscribe@googlegroups.com.
To view this discussion on the web visit https://groups.google.com/d/msgid/materials-welding/CAL2L2JPmE1-fs5i4yTsZDGE0rSrGranX1zp2SZbMYUTJuPv6HA%40mail.gmail.com.

No comments:

Re: [MW:35289] Welding consumable for S355J2WP material

S355 J2 WP  is a weathering structural steel  It has better atmospheric corrosion resistance. Use E 8018 - W1/W2  Electrodes This is regular...